Celldisk and Griddisk are Not Created Automatically on Oracle Full Rack Exadata Cell Node

Oracle Exadata Troubleshooting

In this post we will demonstrate how to create the Cell Disk and Grid disks manually, add them to the respective ASM Disk Group on Oracle Full Rack Exadata Cell Node.

The Exadata Machine is expected to be up and running and the storage cell containing the failed drive to boot and be available. If an Exadata machine “or between another Exadata or an Exadata interconnected by an Exadata” has more than one drive to replace, it is critical to replace only one DRIVE to avoid the risk of data loss. Before replacing another disk in Exadata, make sure that the balancing is complete after the first replacement.

Before proceeding, confirm that the part number (logistics or on-site spare part) of the part at hand matches the part number shipped for part replacement “especially important if the customer has multiple shelves of different drive types / sizes”.

You can read the post for insufficient privileges warning.

CellCLI> list celldisk attributes name, size, status


CD_00_sp000cel02 8.9094085693359375T normal
CD_01_sp000cel02 8.9094085693359375T normal
CD_02_sp000cel02 8.9094085693359375T normal
CD_03_sp000cel02 8.9094085693359375T normal
CD_04_sp000cel02 8.9094085693359375T normal
CD_05_sp000cel02 8.9094085693359375T normal
CD_06_sp000cel02 8.9094085693359375T not present
CD_07_sp000cel02 8.9094085693359375T normal
CD_08_sp000cel02 8.9094085693359375T normal
CD_09_sp000cel02 8.9094085693359375T normal
CD_10_sp000cel02 8.9094085693359375T normal
CD_11_sp000cel02 8.9094085693359375T normal
FD_00_ru04 5.8218994140625T normal
FD_01_ru04 5.8218994140625T normal
FD_02_ru04 5.8218994140625T normal
FD_03_ru04 5.8218994140625T normal

CellCLI> list alerthistory


8_1 2019-10-17T09:11:54+03:00 warning “Data hard disk entered confinement offline status. The LUN 0_6 changed status to warning – confinedOffline. CellDisk changed status to normal – confinedOffline. All subsequent I/Os on this disk are failed immediately. Confinement tests will be run on the disk to determine if the disk should be dropped. Status : WARNING – CONFINEDOFFLINE Manufacturer : HGST Model Number : H7210A520SUN010T Size : 010T Serial Number : 1745R5H38K Firmware : A374 Slot Number : 6 Cell Disk : CD_06_sp000cel02 Grid Disk : DATAC1_CD_06_sp000cel02, RECOC1_CD_06_sp000cel02 Reason for confinement : threshold for service time exceeded”
8_2 2019-10-17T09:20:15+03:00 critical “Data hard disk entered poor performance status. The LUN 0_6 changed status to warning – poor performance. CellDisk changed status to proactive failure. Status : WARNING – POOR PERFORMANCE Manufacturer : HGST Model Number : H7210A520SUN010T Size : 010T Serial Number : 1745R5H38K Firmware : A374 Slot Number : 6 Cell Disk : CD_06_sp000cel02 Grid Disk : DATAC1_CD_06_sp000cel02, RECOC1_CD_06_sp000cel02 Reason for poor performance : threshold for service time exceeded”
8_3 2019-10-17T13:06:38+03:00 warning “Oracle Exadata completed the rebalance operation triggered by the drop operation on the following ASM disks. ASM Disk Name : DATAC1_CD_06_SP000CEL02, RECOC1_CD_06_SP000CEL02 ASM Diskgroup : DATAC1, RECOC1 Grid Disk : DATAC1_CD_06_sp000cel02, RECOC1_CD_06_sp000cel02 Cell Disk : CD_06_sp000cel02 Physical Disk : 252:6 Physical Disk Status : warning – poor performance “
8_4 2019-12-06T10:27:21+03:00 clear “Data hard disk was replaced. Status : NORMAL Manufacturer : HGST Model Number : H7210A520SUN010T Size : 10TB Serial Number : 1910R0NJKD Firmware : A3Y1 Slot Number : 6 Cell Disk : Not configured Grid Disk : Not configured”

CellCLI> create celldisk CD_06_sp000cel02 lun=0_6
CELL-02526: Pre-existing cell disk: CD_06_sp000cel02

CellCLI> list celldisk attributes all
CD_00_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdc /dev/sdc HardDisk 0 0 f205383a-e5c4-44b7-9720-e6b45648c782 R5H2UK 8.9094085693359375T normal
CD_01_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdd /dev/sdd HardDisk 0 0 2b4caf5b-0dc0-4875-b38e-284d1082094e R5KKMK 8.9094085693359375T normal
CD_02_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sde /dev/sde HardDisk 0 0 9e9d8d01-982a-46f7-a3e5-e08be796079f R5GUDK 8.9094085693359375T normal
CD_03_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdf /dev/sdf HardDisk 0 0 129b0074-f4f4-497c-9051-b5d30b6bc6cb R5GTAK 8.9094085693359375T normal
CD_04_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdg /dev/sdg HardDisk 0 0 44c50b57-87af-4974-bbc1-7e0c700ee2b5 R5GUSK 8.9094085693359375T normal
CD_05_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdh /dev/sdh HardDisk 0 0 a4ddf05e-782e-443f-9c21-9fcbd77a061c R5GJEK 8.9094085693359375T normal
CD_06_sp000cel02 2018-05-31T11:42:01+03:00 HardDisk 5 0 9ab85ce5-8b29-4f5f-95b3-e6219440a154 R5H38K 8.9094085693359375T not present
CD_07_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdj /dev/sdj HardDisk 0 0 8a52f09c-735b-4353-b093-373f1ff648f3 R5L1TK 8.9094085693359375T normal
CD_08_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdk /dev/sdk HardDisk 0 0 93bad4df-56fc-404e-8bca-426477fefdcf R5KP1K 8.9094085693359375T normal
CD_09_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdl /dev/sdl HardDisk 0 0 9527acd7-df19-4aeb-84a4-a9bc964b044e R5KVKK 8.9094085693359375T normal
CD_10_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdm /dev/sdm HardDisk 0 0 370fb3d0-707f-4643-8b04-7c984a0a88c4 R5KYLK 8.9094085693359375T normal
CD_11_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdn /dev/sdn HardDisk 0 0 1ef9fa7c-3792-41d0-82ed-664d7b8ec992 R5L5DK 8.9094085693359375T normal
FD_00_ru04 2018-04-06T19:08:30+03:00 /dev/md310 /dev/md310 FlashDisk 0 0 784fc92e-9656-4590-97ea-57aae609566c PHLE747100MX6P4BGN-2,PHLE747100MX6P4BGN-1 5.8218994140625T normal
FD_01_ru04 2018-04-06T19:08:30+03:00 /dev/md304 /dev/md304 FlashDisk 0 0 e7e10e2d-4c97-4763-a562-1b4b473caa27 PHLE747100ND6P4BGN-2,PHLE747100ND6P4BGN-1 5.8218994140625T normal
FD_02_ru04 2018-04-06T19:08:30+03:00 /dev/md305 /dev/md305 FlashDisk 0 0 d1d8bde0-0471-426f-aea4-c06d1bed98e1 PHLE747100WN6P4BGN-2,PHLE747100WN6P4BGN-1 5.8218994140625T normal
FD_03_ru04 2018-04-06T19:08:30+03:00 /dev/md306 /dev/md306 FlashDisk 0 0 eb700e2a-d07e-4d57-ae9f-11f22ebc0b7a PHLE747100WZ6P4BGN-2,PHLE747100WZ6P4BGN-1 5.8218994140625T normal

CellCLI> alter lun 0_6 reenable force
LUN 0_6 successfully reenabled.

CellCLI> drop celldisk CD_06_sp000cel02 force;
CellDisk CD_06_sp000cel02 successfully dropped

CellCLI> list celldisk attributes all
CD_00_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdc /dev/sdc HardDisk 0 0 f205383a-e5c4-44b7-9720-e6b45648c782 R5H2UK 8.9094085693359375T normal
CD_01_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdd /dev/sdd HardDisk 0 0 2b4caf5b-0dc0-4875-b38e-284d1082094e R5KKMK 8.9094085693359375T normal
CD_02_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sde /dev/sde HardDisk 0 0 9e9d8d01-982a-46f7-a3e5-e08be796079f R5GUDK 8.9094085693359375T normal
CD_03_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdf /dev/sdf HardDisk 0 0 129b0074-f4f4-497c-9051-b5d30b6bc6cb R5GTAK 8.9094085693359375T normal
CD_04_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdg /dev/sdg HardDisk 0 0 44c50b57-87af-4974-bbc1-7e0c700ee2b5 R5GUSK 8.9094085693359375T normal
CD_05_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdh /dev/sdh HardDisk 0 0 a4ddf05e-782e-443f-9c21-9fcbd77a061c R5GJEK 8.9094085693359375T normal
CD_07_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdj /dev/sdj HardDisk 0 0 8a52f09c-735b-4353-b093-373f1ff648f3 R5L1TK 8.9094085693359375T normal
CD_08_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdk /dev/sdk HardDisk 0 0 93bad4df-56fc-404e-8bca-426477fefdcf R5KP1K 8.9094085693359375T normal
CD_09_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdl /dev/sdl HardDisk 0 0 9527acd7-df19-4aeb-84a4-a9bc964b044e R5KVKK 8.9094085693359375T normal
CD_10_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdm /dev/sdm HardDisk 0 0 370fb3d0-707f-4643-8b04-7c984a0a88c4 R5KYLK 8.9094085693359375T normal
CD_11_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdn /dev/sdn HardDisk 0 0 1ef9fa7c-3792-41d0-82ed-664d7b8ec992 R5L5DK 8.9094085693359375T normal
FD_00_ru04 2018-04-06T19:08:30+03:00 /dev/md310 /dev/md310 FlashDisk 0 0 784fc92e-9656-4590-97ea-57aae609566c PHLE747100MX6P4BGN-2,PHLE747100MX6P4BGN-1 5.8218994140625T normal
FD_01_ru04 2018-04-06T19:08:30+03:00 /dev/md304 /dev/md304 FlashDisk 0 0 e7e10e2d-4c97-4763-a562-1b4b473caa27 PHLE747100ND6P4BGN-2,PHLE747100ND6P4BGN-1 5.8218994140625T normal
FD_02_ru04 2018-04-06T19:08:30+03:00 /dev/md305 /dev/md305 FlashDisk 0 0 d1d8bde0-0471-426f-aea4-c06d1bed98e1 PHLE747100WN6P4BGN-2,PHLE747100WN6P4BGN-1 5.8218994140625T normal
FD_03_ru04 2018-04-06T19:08:30+03:00 /dev/md306 /dev/md306 FlashDisk 0 0 eb700e2a-d07e-4d57-ae9f-11f22ebc0b7a PHLE747100WZ6P4BGN-2,PHLE747100WZ6P4BGN-1 5.8218994140625T normal

CellCLI> create celldisk CD_06_sp000cel02 lun=0_6
CellDisk CD_06_sp000cel02 successfully created

CellCLI> list celldisk attributes all


CD_00_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdc /dev/sdc HardDisk 0 0 f205383a-e5c4-44b7-9720-e6b45648c782 R5H2UK 8.9094085693359375T normal
CD_01_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdd /dev/sdd HardDisk 0 0 2b4caf5b-0dc0-4875-b38e-284d1082094e R5KKMK 8.9094085693359375T normal
CD_02_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sde /dev/sde HardDisk 0 0 9e9d8d01-982a-46f7-a3e5-e08be796079f R5GUDK 8.9094085693359375T normal
CD_03_sp000cel02 2018-05-31T11:42:00+03:00 /dev/sdf /dev/sdf HardDisk 0 0 129b0074-f4f4-497c-9051-b5d30b6bc6cb R5GTAK 8.9094085693359375T normal
CD_04_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdg /dev/sdg HardDisk 0 0 44c50b57-87af-4974-bbc1-7e0c700ee2b5 R5GUSK 8.9094085693359375T normal
CD_05_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdh /dev/sdh HardDisk 0 0 a4ddf05e-782e-443f-9c21-9fcbd77a061c R5GJEK 8.9094085693359375T normal
CD_06_sp000cel02 2019-12-09T11:20:13+03:00 /dev/sdi /dev/sdi HardDisk 0 8.90936279296875T 675bf824-870b-419f-a0eb-923588c6389e R0NJKD 8.9094085693359375T normal
CD_07_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdj /dev/sdj HardDisk 0 0 8a52f09c-735b-4353-b093-373f1ff648f3 R5L1TK 8.9094085693359375T normal
CD_08_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdk /dev/sdk HardDisk 0 0 93bad4df-56fc-404e-8bca-426477fefdcf R5KP1K 8.9094085693359375T normal
CD_09_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdl /dev/sdl HardDisk 0 0 9527acd7-df19-4aeb-84a4-a9bc964b044e R5KVKK 8.9094085693359375T normal
CD_10_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdm /dev/sdm HardDisk 0 0 370fb3d0-707f-4643-8b04-7c984a0a88c4 R5KYLK 8.9094085693359375T normal
CD_11_sp000cel02 2018-05-31T11:42:01+03:00 /dev/sdn /dev/sdn HardDisk 0 0 1ef9fa7c-3792-41d0-82ed-664d7b8ec992 R5L5DK 8.9094085693359375T normal
FD_00_ru04 2018-04-06T19:08:30+03:00 /dev/md310 /dev/md310 FlashDisk 0 0 784fc92e-9656-4590-97ea-57aae609566c PHLE747100MX6P4BGN-2,PHLE747100MX6P4BGN-1 5.8218994140625T normal
FD_01_ru04 2018-04-06T19:08:30+03:00 /dev/md304 /dev/md304 FlashDisk 0 0 e7e10e2d-4c97-4763-a562-1b4b473caa27 PHLE747100ND6P4BGN-2,PHLE747100ND6P4BGN-1 5.8218994140625T normal
FD_02_ru04 2018-04-06T19:08:30+03:00 /dev/md305 /dev/md305 FlashDisk 0 0 d1d8bde0-0471-426f-aea4-c06d1bed98e1 PHLE747100WN6P4BGN-2,PHLE747100WN6P4BGN-1 5.8218994140625T normal
FD_03_ru04 2018-04-06T19:08:30+03:00 /dev/md306 /dev/md306 FlashDisk 0 0 eb700e2a-d07e-4d57-ae9f-11f22ebc0b7a PHLE747100WZ6P4BGN-2,PHLE747100WZ6P4BGN-1 5.8218994140625T normal

CellCLI> list griddisk attributes all


DATAC1_CD_00_sp000cel02 DATAC1 DATAC1_CD_00_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_00_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 c5eef73c-6555-4148-83b5-b429326528ef 7.63671875T active
DATAC1_CD_01_sp000cel02 DATAC1 DATAC1_CD_01_SP000CEL02 SP000CEL02 FD_02_ru04 default CD_01_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 3198a298-b12a-4903-bd58-bc296c139131 7.63671875T active
DATAC1_CD_02_sp000cel02 DATAC1 DATAC1_CD_02_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_02_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:33+03:00 HardDisk 0 5dea7d00-7a88-4999-8e45-26417bc65225 7.63671875T active
DATAC1_CD_03_sp000cel02 DATAC1 DATAC1_CD_03_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_03_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 58908c74-8735-4126-bc0f-6fb66b525595 7.63671875T active
DATAC1_CD_04_sp000cel02 DATAC1 DATAC1_CD_04_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_04_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:33+03:00 HardDisk 0 d617aaf5-1277-4376-ad55-03f93bf45774 7.63671875T active
DATAC1_CD_05_sp000cel02 DATAC1 DATAC1_CD_05_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_05_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 82dad0a8-c9bc-4bd5-beb4-525668a2f233 7.63671875T active
DATAC1_CD_07_sp000cel02 DATAC1 DATAC1_CD_07_SP000CEL02 SP000CEL02 FD_02_ru04 default CD_07_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 79cbb3a2-4782-4570-8012-a8ac2b3b120d 7.63671875T active
DATAC1_CD_08_sp000cel02 DATAC1 DATAC1_CD_08_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_08_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 438a5f20-f7d7-44f6-9275-f62357de8f4b 7.63671875T active
DATAC1_CD_09_sp000cel02 DATAC1 DATAC1_CD_09_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_09_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 0f16972d-623b-41c6-8e11-715f802bce78 7.63671875T active
DATAC1_CD_10_sp000cel02 DATAC1 DATAC1_CD_10_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_10_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 9af83af8-a2b4-46f6-921a-82a1129b0a41 7.63671875T active
DATAC1_CD_11_sp000cel02 DATAC1 DATAC1_CD_11_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_11_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 c962c335-15b7-45e6-976c-c15b3fce7404 7.63671875T active
RECOC1_CD_00_sp000cel02 RECOC1 RECOC1_CD_00_SP000CEL02 SP000CEL02 none CD_00_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 ee586a07-a2df-4ce0-9458-39b3057c08d3 1.27264404296875T active
RECOC1_CD_01_sp000cel02 RECOC1 RECOC1_CD_01_SP000CEL02 SP000CEL02 none CD_01_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 f812b1c8-a13d-47b4-90e3-598eabe29994 1.27264404296875T active
RECOC1_CD_02_sp000cel02 RECOC1 RECOC1_CD_02_SP000CEL02 SP000CEL02 none CD_02_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 f45cfe75-3c52-4b02-84eb-a33b9a26aa28 1.27264404296875T active
RECOC1_CD_03_sp000cel02 RECOC1 RECOC1_CD_03_SP000CEL02 SP000CEL02 none CD_03_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 1dbafa3d-27b6-4779-bad3-73a535994e15 1.27264404296875T active
RECOC1_CD_04_sp000cel02 RECOC1 RECOC1_CD_04_SP000CEL02 SP000CEL02 none CD_04_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:55+03:00 HardDisk 0 bfba9d1c-c416-48e1-9aa4-c69ce9811c2a 1.27264404296875T active
RECOC1_CD_05_sp000cel02 RECOC1 RECOC1_CD_05_SP000CEL02 SP000CEL02 none CD_05_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 d75eef69-36b1-488f-b468-9890946fecf1 1.27264404296875T active
RECOC1_CD_07_sp000cel02 RECOC1 RECOC1_CD_07_SP000CEL02 SP000CEL02 none CD_07_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 9bdda41d-e4ed-46c6-8c72-99eba1b6f4bf 1.27264404296875T active
RECOC1_CD_08_sp000cel02 RECOC1 RECOC1_CD_08_SP000CEL02 SP000CEL02 none CD_08_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 21a4f117-27ee-4cc2-b7dd-10f219d6693f 1.27264404296875T active
RECOC1_CD_09_sp000cel02 RECOC1 RECOC1_CD_09_SP000CEL02 SP000CEL02 none CD_09_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 c5e5b72a-42e5-40a6-a455-cbf2d4bb7c6e 1.27264404296875T active
RECOC1_CD_10_sp000cel02 RECOC1 RECOC1_CD_10_SP000CEL02 SP000CEL02 none CD_10_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:55+03:00 HardDisk 0 0831160e-7c44-48b6-99e4-ebe08b808f4b 1.27264404296875T active
RECOC1_CD_11_sp000cel02 RECOC1 RECOC1_CD_11_SP000CEL02 SP000CEL02 none CD_11_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 8e827a24-acd1-470e-961d-e4203ea571ef 1.27264404296875T active

CellCLI> create griddisk DATAC1_CD_06_sp000cel02 celldisk=CD_06_sp000cel02,size=7.63671875T
GridDisk DATAC1_CD_06_sp000cel02 successfully created

CellCLI> create griddisk RECOC1_CD_06_sp000cel02 celldisk=CD_06_sp000cel02,size=1.27264404296875T,cachingPolicy=none
GridDisk RECOC1_CD_06_sp000cel02 successfully created

CellCLI> list griddisk attributes all


DATAC1_CD_00_sp000cel02 DATAC1 DATAC1_CD_00_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_00_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 c5eef73c-6555-4148-83b5-b429326528ef 7.63671875T active
DATAC1_CD_01_sp000cel02 DATAC1 DATAC1_CD_01_SP000CEL02 SP000CEL02 FD_02_ru04 default CD_01_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 3198a298-b12a-4903-bd58-bc296c139131 7.63671875T active
DATAC1_CD_02_sp000cel02 DATAC1 DATAC1_CD_02_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_02_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:33+03:00 HardDisk 0 5dea7d00-7a88-4999-8e45-26417bc65225 7.63671875T active
DATAC1_CD_03_sp000cel02 DATAC1 DATAC1_CD_03_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_03_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 58908c74-8735-4126-bc0f-6fb66b525595 7.63671875T active
DATAC1_CD_04_sp000cel02 DATAC1 DATAC1_CD_04_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_04_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:33+03:00 HardDisk 0 d617aaf5-1277-4376-ad55-03f93bf45774 7.63671875T active
DATAC1_CD_05_sp000cel02 DATAC1 DATAC1_CD_05_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_05_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 82dad0a8-c9bc-4bd5-beb4-525668a2f233 7.63671875T active
DATAC1_CD_06_sp000cel02 default CD_06_sp000cel02 2019-12-09T11:33:46+03:00 HardDisk 0 9b655e91-a419-4272-bdb7-3a1194ccba3e 7.63671875T active
DATAC1_CD_07_sp000cel02 DATAC1 DATAC1_CD_07_SP000CEL02 SP000CEL02 FD_02_ru04 default CD_07_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 79cbb3a2-4782-4570-8012-a8ac2b3b120d 7.63671875T active
DATAC1_CD_08_sp000cel02 DATAC1 DATAC1_CD_08_SP000CEL02 SP000CEL02 FD_00_ru04 default CD_08_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 438a5f20-f7d7-44f6-9275-f62357de8f4b 7.63671875T active
DATAC1_CD_09_sp000cel02 DATAC1 DATAC1_CD_09_SP000CEL02 SP000CEL02 FD_01_ru04 default CD_09_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 0f16972d-623b-41c6-8e11-715f802bce78 7.63671875T active
DATAC1_CD_10_sp000cel02 DATAC1 DATAC1_CD_10_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_10_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:32+03:00 HardDisk 0 9af83af8-a2b4-46f6-921a-82a1129b0a41 7.63671875T active
DATAC1_CD_11_sp000cel02 DATAC1 DATAC1_CD_11_SP000CEL02 SP000CEL02 FD_03_ru04 default CD_11_sp000cel02 “Cluster sphubdb-cluster diskgroup DATAC1” 2018-05-31T11:49:34+03:00 HardDisk 0 c962c335-15b7-45e6-976c-c15b3fce7404 7.63671875T active
RECOC1_CD_00_sp000cel02 RECOC1 RECOC1_CD_00_SP000CEL02 SP000CEL02 none CD_00_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 ee586a07-a2df-4ce0-9458-39b3057c08d3 1.27264404296875T active
RECOC1_CD_01_sp000cel02 RECOC1 RECOC1_CD_01_SP000CEL02 SP000CEL02 none CD_01_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 f812b1c8-a13d-47b4-90e3-598eabe29994 1.27264404296875T active
RECOC1_CD_02_sp000cel02 RECOC1 RECOC1_CD_02_SP000CEL02 SP000CEL02 none CD_02_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 f45cfe75-3c52-4b02-84eb-a33b9a26aa28 1.27264404296875T active
RECOC1_CD_03_sp000cel02 RECOC1 RECOC1_CD_03_SP000CEL02 SP000CEL02 none CD_03_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:56+03:00 HardDisk 0 1dbafa3d-27b6-4779-bad3-73a535994e15 1.27264404296875T active
RECOC1_CD_04_sp000cel02 RECOC1 RECOC1_CD_04_SP000CEL02 SP000CEL02 none CD_04_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:55+03:00 HardDisk 0 bfba9d1c-c416-48e1-9aa4-c69ce9811c2a 1.27264404296875T active
RECOC1_CD_05_sp000cel02 RECOC1 RECOC1_CD_05_SP000CEL02 SP000CEL02 none CD_05_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 d75eef69-36b1-488f-b468-9890946fecf1 1.27264404296875T active
RECOC1_CD_06_sp000cel02 none CD_06_sp000cel02 2019-12-09T11:33:53+03:00 HardDisk 0 3b8f8cb9-a1d9-4918-9e14-b11cf604fc4e 1.27264404296875T active
RECOC1_CD_07_sp000cel02 RECOC1 RECOC1_CD_07_SP000CEL02 SP000CEL02 none CD_07_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 9bdda41d-e4ed-46c6-8c72-99eba1b6f4bf 1.27264404296875T active
RECOC1_CD_08_sp000cel02 RECOC1 RECOC1_CD_08_SP000CEL02 SP000CEL02 none CD_08_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 21a4f117-27ee-4cc2-b7dd-10f219d6693f 1.27264404296875T active
RECOC1_CD_09_sp000cel02 RECOC1 RECOC1_CD_09_SP000CEL02 SP000CEL02 none CD_09_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 c5e5b72a-42e5-40a6-a455-cbf2d4bb7c6e 1.27264404296875T active
RECOC1_CD_10_sp000cel02 RECOC1 RECOC1_CD_10_SP000CEL02 SP000CEL02 none CD_10_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:55+03:00 HardDisk 0 0831160e-7c44-48b6-99e4-ebe08b808f4b 1.27264404296875T active
RECOC1_CD_11_sp000cel02 RECOC1 RECOC1_CD_11_SP000CEL02 SP000CEL02 none CD_11_sp000cel02 “Cluster sphubdb-cluster diskgroup RECOC1” 2018-05-31T11:50:54+03:00 HardDisk 0 8e827a24-acd1-470e-961d-e4203ea571ef 1.27264404296875T active

SQL> r
1* select name, path, failgroup, state, header_status from v$asm_disk where path like ‘%sp000cel02’

NAME PATH FAILGROUP STATE HEADER_STATU


o/10.0.0.1;10.0.0.2/DATAC1_CD_06_sp000cel02 sp000cel02 NORMAL CANDIDATE
o/10.0.0.1;10.0.0.2/RECOC1_CD_06_sp000cel02 sp000cel02 NORMAL CANDIDATE

DATAC1_CD_08_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_08_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_10_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_10_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_11_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_11_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_00_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_00_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_04_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_04_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_07_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_07_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_05_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_05_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_08_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_08_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_09_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_09_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_10_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_10_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_09_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_09_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_01_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_01_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_05_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_05_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_02_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_02_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_04_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_04_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_03_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_03_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_00_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_00_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_07_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_07_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_11_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_11_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_03_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_03_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_02_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_02_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_01_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_01_sp000cel02 SP000CEL02 NORMAL MEMBER

SQL> alter diskgroup DATAC1 add failgroup SP000CEL02 disk ‘o/10.0.0.1;10.0.0.2/DATAC1_CD_06_sp000cel02’;

Diskgroup altered.

SQL> alter diskgroup RECOC1 add failgroup SP000CEL02 disk ‘o/10.0.0.1;10.0.0.2/RECOC1_CD_06_sp000cel02’;

Diskgroup altered.

SQL> select name, path, failgroup, state, header_status from v$asm_disk where path like ‘%sp000cel02’;

NAME PATH FAILGROUP STATE HEADER_STATU


DATAC1_CD_08_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_08_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_10_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_10_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_11_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_11_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_06_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_06_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_00_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_00_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_04_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_04_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_07_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_07_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_05_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_05_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_08_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_08_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_09_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_09_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_06_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_06_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_10_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_10_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_09_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_09_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_01_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_01_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_05_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_05_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_02_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_02_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_04_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_04_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_03_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_03_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_00_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_00_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_07_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_07_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_11_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_11_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_03_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_03_sp000cel02 SP000CEL02 NORMAL MEMBER
RECOC1_CD_02_SP000CEL02 o/10.0.0.1;10.0.0.2/RECOC1_CD_02_sp000cel02 SP000CEL02 NORMAL MEMBER
DATAC1_CD_01_SP000CEL02 o/10.0.0.1;10.0.0.2/DATAC1_CD_01_sp000cel02 SP000CEL02 NORMAL MEMBER

24 rows selected.

Congrat, Have a nice day.